Water Heater Pilot Light Won't Stay Lit
On older gas water heaters, a small pilot flame lights the burner. When it will not stay lit, the cause is usually the thermocouple, a draft, or a gas supply problem.
Short answerFollow the lighting instructions on the label on the heater, and only if you do not smell gas. If the pilot lights but goes out when you release the knob, the thermocouple is the likely culprit.
Common causes
- Thermocouple: this sensor tells the gas valve the pilot is lit. When it wears out or is out of position, the valve shuts the gas off.
- Dirty pilot tube: a weak, yellow or flickering pilot flame may not heat the thermocouple enough.
- Drafts: a heater in a garage or attic can lose its pilot in strong wind or when a door is left open.
- Gas supply: if other gas appliances are also out, the problem is upstream of the heater.
If you smell gas
Do not try to light the pilot. Leave the house and call Atmos Energy at 866-322-8667 from a safe distance (Atmos Energy).
Newer heaters
Many newer gas water heaters use an electronic igniter or a sealed combustion chamber instead of a standing pilot you can reach. Those faults usually show as a blinking status light, and the code on the label tells the plumber where to start. See gas water heater repair.